UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers

Get reliable 25kVA, 37.5kVA, 50kVA, and 75kVA single phase pole mounted transformers with UL/cUL certification. Factory direct prices and quality guaranteed.
Request a Quote

PRODUCTS DETAILS

  • Overview
  • Product Description
  • Product Parameters
  • Standard Features
  • Application
  • Packaging & Shipping
  • Our Advantages
  • Company Profile
Overview

Basic Info.

Model NO.
D-25
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001, UL/cUL CSA
Usage
Single-phase Transformer, Power Transformer, Distribution Transformer, Utilities/New Energy
Frequency Characteristics
50/60Hz
Shape of Core
Stacked Iron Core
Brand
Daelim Belefic
Type
Pole Mounted
Winding Material
Copper/Aluminum
Rated Capacity
10kVA 15kVA 25kVA 37.5kVA 50kVA 100kVA 167kVA 333
Warranty
24 Months
Standard
IEC/ANSI/IEEE/CSA
Primary Voltage
34.5kv 24.94kv 19.2kv 13.8kv 13.2kv 12.47kv
Secondary Voltage
240V 480V 600V
Core Material
Silicon Steel
Product Name
Single Phase Pole Mounted Transformer
No Load Loss
19W-350W
MOQ
6
Vector Group
Dyn11/Yyn0/Yd11/Ynd11/Dyn5
Customization
Accept
Color
Gray or Customized
Bil
125/30kv or Others
Transport Package
Wooden Case
Trademark
Daelim Belefic
Origin
China
Production Capacity
500/Month

Product Description

 
Product Description

A single-phase pole mounted transformer is a special type of single-phase transformer that has a pole mounted shape. It consists of a primary winding and a secondary winding and is primarily used to step up or step down the voltage of AC power.

The single-phase pole mounted transformer typically uses a toroidal core to support and guide the magnetic field. This core is made of a high-permeability material, such as silicon steel, to enhance the efficiency of the transformer and reduce iron losses. The primary and secondary windings are wound around this core and achieve voltage transformation through mutual induction.

Compared to other regular single-phase transformers, the single-phase pole mounted transformer offers several advantages. Firstly, due to its pole mounted shape, it has a smaller size and volume, making it suitable for applications with limited space. Secondly, the pole mounted design provides better heat dissipation, allowing the transformer to cool more effectively and have a higher power density. Additionally, the compact structure of the pole mounted transformer helps to reduce electromagnetic interference and noise.

Single-phase pole mounted transformers find wide applications in industrial, commercial, and residential sectors. In industrial settings, they are often used in power distribution, substations, and control systems. In the commercial sector, they can be employed for power supply in buildings, shopping malls, and office complexes. In homes, they can be used for powering electronic devices, lighting, and other electrical appliances.

UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers
The conventional type of single-phase pole mounted transformer is a common type of power transformer that features a circular core and pole mounted windings. Here is an introduction to the conventional type of single-phase pole mounted transformer:

Compact structure: The conventional type of single-phase pole mounted transformer is designed with a circular core and pole mounted windings, resulting in a compact structure. 

High power density: This type of transformer has a high power density. 

Excellent heat dissipation: The pole mounted shape of the transformer enables effective heat dissipation through the pole mounted enclosure, which provides a large surface area. 

Low electromagnetic noise: The closed structure of the circular core in the conventional pole mounted transformer helps to minimize electromagnetic interference and noise. 
This type of transformers are CSP type, which can protect itself from thunder and lighting, short circuit and protect the transiting and distribution line from current failure because of self-malfunction.
Except from some similarities such as cylinder tank, hooks, lifting lugs, grounding devices, nameplates, core and winding with the conventional type. This type of transformers have characteristics and devices as follows:

1) One or two high voltage bushings are on the cover with fuse.
2) One or two arresters are installed on the wall of the tank, whose top end is near to the high voltage bushing, and connected to the bushing by a copper strip. One secondary breaker switch is above the winding inside the tank, and here are operating handle,overload reset and signal light.
3) Low voltage bushing is educed from the wall of the tank, grounding device is fixed to position X2. One end of the single
bushing leads out through the high voltage bushing, the other end is ground connection.
4) All units are built in accordance with IEC60076, ANSI/IEEEC57.12.20, CSA C2.1-06,CSA C2.2-06 and etc.
UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers
Product Parameters
Rated Power
(KVA)
High Voltage
(KV)
Low Voltage
(KV)
No-load Loss
(W)
On-load Loss Oil Weight
(KG)
Total Weight
(KG)
10 34500/
19920
13800/
7957
13200/
7620
12470/
7200
or others
120-240
240-480
347
600
36 120 22 150
15 50 195 30 210
25 80 290 45 258
37.5 105 360 50 340
50 135 500 62 395
75 190 650 88 480
100 210 850 94 530
167 350 1410 138 680
333 - - - -
 
Standard Features
UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers
UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers
UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers



Δ Quality System ISO 9001 certified.
Δ Paint system meeting or exceeding the performance of the IEEEC57.12.28 Standard including the salt spray test.
Δ Lifting lugs meeting all of the requirements of the CSA C2.1-06 and CSA C2.2-06 Standard
Δ Computer aided design for mechanical & electrical calculations (C.A.D.).
Δ Core and coils designed for an optimum Total Ownership Cost (TOC).
Δ Low voltage leads with embossed markings on all units with 3 L V bushings for easy reading and permanent identification on selected ratings.
Δ Provision for surge arrester bracket,bracket available as an option.

Δ "Low-high-low"windings for increased short circuit stren-gth,efficiency and thermal strength
Δ Cover or sidewall mounted high voltage bushing(s)as required.
Δ Wound core with step-lap joints for increased efficiency and lower noise levels.
Δ Dual voltage designed to meet BIL and short circuit requirements on both connections.
Δ Automatic self-resealing pressure relief valve.
Δ Low voltage spade or clamp type(basket)terminals as required.
Δ Multiple cover clamps to ensure proper sealing and to minimize water retention on the cover edge.

Application
UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers
UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers
UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers
Packaging & Shipping
UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers
UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers

As shown in the picture above, Daelim transformers are packed in wooden case. Put the transformer on a solid wooden pallet for fixing, and protect it with wooden boards on the top and around. Such wooden case packaging ensures that the transformer will avoid damage caused by impact during transportation.

The other type of packaging in the picture above is wooden pallet packaging.
This packaging method of transformers is usually used for full container transportation by sea. After wrapping the transformer with plastic film (moisture and scratch protection), fix it on the log pallet.
 

Our Advantages

1. Certifications
Daelim is a professional transformer manufacturer and supplier. Various international standards can be customized for your transformer, such as: IEEE/ANSI, CSA, AS/NZS, IEC, EN 60076, GOST, etc.Daelim produces transformers with UL/cUL, CSA, CESI etc certifications.

2. Transformer Quality
Daelim has a very serious quality control system, strictly controlling every detail from transformer design to raw material procurement, assembly, testing, packaging and delivery. UL third-party agency regularly inspects the manufacturing process of Daelim transformers. This ensures Daelim maintains high quality standards even after its products have completed initial UL testing.
3. After Sales Service

a. Up to 24 months quality guarantee period. If there is any problem in the operation of your transformer, Daelim's after-sales team will solve it promptly and quickly;
b. Local after-sales installation service team. Whether you are in North America, South America or other regions, Daelim's local team can provide you with professional transformer installation, commissioning, maintenance and other services;
c. Daelim provides remote video guidance for transformer installation.
 

Company Profile

DB Transformer is the top transformer supplier in China. The factory is located in Jiangsu Province, covering an area of 30,000 square meters. With more than 20 years of transformer export experience, the professional technical team can meet your requirements for all technical standards; the professional marketing team will quickly and efficiently promote your transformer project, saving you more time and economic costs.

Various international certifications of transformers to ensure product quality, safety and reliability. The practical application of DB Transformer in nearly a hundred countries will make you more confident in DB Transformer. DB Transformer will be your good choice.
UL/cUL Certificated 25kVA 37.5kVA 50kVA 75kVA Single Phase Pole Mounted Transformers

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours