Tbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power Transformer

Get high-quality Tbbx 12kv 1600kvar medium voltage reactive compensation electric distribution cabinet substation power transformers from our factory. Contact us now!
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
TBBX 12KV 1600kvar
Electrolyte
Electrolytic
Usage
Low Frequency Coupling, Tuning, Filter, Low Frequency Bypass
Tuning
Polystyrene Capacitor
Filter
Composite Paper Capacitor
Compensate
Reactive Energy
Power Transformer
Prove Transmission Power Factor
Using Range
Motor or Inductive Power
Power Supply
Only Supply Reactive for Load
Warranty
2 Years
Di Electrical
50 Degree Solid Wax
Transport Package
Wooden
Specification
CE ROHS
Trademark
OEM
Origin
Zhejiang Yueqing
HS Code
85321000
Production Capacity
100000PCS/ Month

Product Description

TBBX 12KV 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet substation power transformer 
1.match for mainly transmission high voltage power transformer ,supply reactive power 
2. let power transformer only supply active power , improve power quality  

high voltage fiexd reactive compensation complete set/ deviceswitchgear panel(hereinafter referred to as the device) is suitable for 6-35kV AC power system with frequency of 50Hz. It is mainly used in power system to adjust bus voltage and reactive power, improve power factor, improve voltage quality and reduce network loss.

We can provide the most appropriate, the most reasonable solution according to the customer's requirements. As long as you tell us your requirements or drawings, we can provide a complete solution. And the main components, according to your requirements, choose the brand, Or we can provide cost-effective components to reduce your purchase cost.

Main technical performance index

1.Capacitance deviation

1.1The difference between the actual capacitance and the rated capacitance of the device is within the range of 0- +5% of the rated capacitance. The standard is higher than other factories

1.2The ratio of the maximum to the minimum capacitance between any two line terminals of the device shall not exceed 1.02.

2.Inductance deviation

2.1Under rated current, the allowable deviation of reactance value is 0~+5%.



2.2The reactance value of each phase shall not exceed ± 2% of the average value of three phases
Tbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power TransformerTbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power TransformerTbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power TransformerTbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power Transformer

Tbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power Transformer


Tbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power Transformer Tbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power Transformer Tbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power Transformer Tbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power Transformer Tbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power Transformer Tbbx 12kv 1600kvar Medium Voltage Reactive Compensation Electric Distribution Cabinet Substation Power Transformer

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours