Basic Info.
Model NO.
D11
Tank Design
Cy Linder Tank Single-Phase Transformer
Coil Material
Copper
Product Feature
Distribution Transformer Price
Installtion
Pole Mounted Trasnformer
Color
Grey or Optional
Transport Package
Seaworthy Wooden Case
Trademark
Farady
Origin
China
HS Code
85042100
Production Capacity
20000
Product Description
Application
The Farady overhead transformer may be used alone for the supply of a single phase load or as one of three
units in a bank for the supply of a three phase load. The unit may be direct mounted to a wooden or concrete pole,
or cluster mounted on a pole for three phase use. Our single phase overhead distribution transformer is
commonly used in various places including rural areas, remote regions and scattered villages to provide high
quality power supply for daily lighting, agricultural production and industrial plants. Aside from these, it is also
suitable for the energy saving projects for railway and urban grid.
Standards
IEEE Std C57.12.00™-2000 standard - IEEE Standard for Standard General Requirements for
Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE Std C57.12.20™-2005 standard - IEEE Standard for Overhead-Type Distribution Transformers, 500kVA
and Smaller: High Voltage, 34500V and Below; Low Voltage, 7970/13800Y V and below
IEEE Std C57.12.31™-2010 standard - IEEE Standard for Pole Mounted Equipment - Enclosure Integrity
IEEE Std C57.12.35™-1996 standard - IEEE Standard for Bar Coding for Distribution Transformers
IEEE Std C57.12.90™-2006 standard - IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and
Regulating Transformers
IEEE Std C57.12.91™-2001 standard - IEEE Guide for Loading Mineral-Oil-Immersed Transformers
IEEE Std C57.154™-2012 standard (Pending Approval)- IEEE Standard for the Design, Testing and Application
of Liquid-Immersed Distribution, Power and Regulated Transformers using High-Temperature
Insulation Systems and Operating at Elevated Temperatures
(ASTM)American Society for Testing Materials
NEMA TR 1-1993 (R2000) - Transformers, Regulators and Reactors, Table 0-2 Audible Sound Levels
10 CFR Part 431 - Department of Energy - Energy Conservation Program for Commercial Equipment:
Distribution Transformers Energy Conservation Standards; Final Rule
Service condition
a) Suitable for both indoor or outdoor
b)Air temperature: Maximum temperature: +40ºC; Minimum temperature:-25ºC
c) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
d) Altitude above sea level: Maximum installation altitude: 2000m.
e) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
f) No frequent violent shake
Note: * Beyond those services condition should enquiry to manufacturer technical dept during order
Rating Details
General technical information is listed below:
Information on less common requirements can be obtained through Farady sale department
-kVA: 3kVA through 167kVA
-Temperature rise : 65ºC
-Cooling type: ONAN
-Working Frequency: 50/60Hz
-Polarity: additive or Subtractive
-Core type : CRGO or Amorphous
-Protection: CSP or not
Product structure
outline demensions
Packing & Delivery
Our Company
The Farady overhead transformer may be used alone for the supply of a single phase load or as one of three
units in a bank for the supply of a three phase load. The unit may be direct mounted to a wooden or concrete pole,
or cluster mounted on a pole for three phase use. Our single phase overhead distribution transformer is
commonly used in various places including rural areas, remote regions and scattered villages to provide high
quality power supply for daily lighting, agricultural production and industrial plants. Aside from these, it is also
suitable for the energy saving projects for railway and urban grid.
Standards
IEEE Std C57.12.00™-2000 standard - IEEE Standard for Standard General Requirements for
Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE Std C57.12.20™-2005 standard - IEEE Standard for Overhead-Type Distribution Transformers, 500kVA
and Smaller: High Voltage, 34500V and Below; Low Voltage, 7970/13800Y V and below
IEEE Std C57.12.31™-2010 standard - IEEE Standard for Pole Mounted Equipment - Enclosure Integrity
IEEE Std C57.12.35™-1996 standard - IEEE Standard for Bar Coding for Distribution Transformers
IEEE Std C57.12.90™-2006 standard - IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and
Regulating Transformers
IEEE Std C57.12.91™-2001 standard - IEEE Guide for Loading Mineral-Oil-Immersed Transformers
IEEE Std C57.154™-2012 standard (Pending Approval)- IEEE Standard for the Design, Testing and Application
of Liquid-Immersed Distribution, Power and Regulated Transformers using High-Temperature
Insulation Systems and Operating at Elevated Temperatures
(ASTM)American Society for Testing Materials
NEMA TR 1-1993 (R2000) - Transformers, Regulators and Reactors, Table 0-2 Audible Sound Levels
10 CFR Part 431 - Department of Energy - Energy Conservation Program for Commercial Equipment:
Distribution Transformers Energy Conservation Standards; Final Rule
Service condition
a) Suitable for both indoor or outdoor
b)Air temperature: Maximum temperature: +40ºC; Minimum temperature:-25ºC
c) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
d) Altitude above sea level: Maximum installation altitude: 2000m.
e) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
f) No frequent violent shake
Note: * Beyond those services condition should enquiry to manufacturer technical dept during order
Rating Details
General technical information is listed below:
Information on less common requirements can be obtained through Farady sale department
-kVA: 3kVA through 167kVA
-Temperature rise : 65ºC
-Cooling type: ONAN
-Working Frequency: 50/60Hz
-Polarity: additive or Subtractive
-Core type : CRGO or Amorphous
-Protection: CSP or not
Product structure
outline demensions
Packing & Delivery
Our Company