Basic Info.
Frequency
50Hz and 60Hz Adjustable
Phase&Wave Form
Single Phase & Pure Sine Wave
AC Voltage
110/120/130 VAC or 220/230/240VAC
Display
LCD and LED
Charge Current Adjustable
Yes
Power Factor
1
Color
Black
Application
Electric Tools
Transport Package
Carton
Specification
CE, ISO
Trademark
ZLpower
Origin
Shenzhen, Guangdong, China
HS Code
8504409900
Production Capacity
10000PCS/Year
Product Description
Application
Solar power system, house, vehicle, ship, navigation and places where lack of city power, mobile electricity work and telecommunications device, launch station, emergency EPS.
6000W Battery Inverter Charger for Solar System and UPS
Main features
1. LCD digital display show voltage, load and battery information in real time.
2. Peak power is three times of rated power.
3. Can work with inductive loads such as air conditioner, motor door and so on
4. Accept generator's energy output.
5. Pure sine wave output, available for sensitive loads.
6. Microprocessor control with 4-step progressive charging, 7 battery type selector.
7. Fast and powerful charger with 35A and 70A.
8. High power factor 0.9-1.0, low power consumption.
9. Automatically transfer between battery and line modes.
10. Custom-made communication port USB/RS-232/SNMP
11. Remote control function.
12. Protection against overload, over temperature, over charging, low battery.
Parameter
Trading terms for reference:
Delivery time: 7-15 work days
Payment terms: TT, LC, Western Union, Money gram.
Warranty: 2 years, 1%-2% spare parts.
Solar power system, house, vehicle, ship, navigation and places where lack of city power, mobile electricity work and telecommunications device, launch station, emergency EPS.
6000W Battery Inverter Charger for Solar System and UPS
Main features
1. LCD digital display show voltage, load and battery information in real time.
2. Peak power is three times of rated power.
3. Can work with inductive loads such as air conditioner, motor door and so on
4. Accept generator's energy output.
5. Pure sine wave output, available for sensitive loads.
6. Microprocessor control with 4-step progressive charging, 7 battery type selector.
7. Fast and powerful charger with 35A and 70A.
8. High power factor 0.9-1.0, low power consumption.
9. Automatically transfer between battery and line modes.
10. Custom-made communication port USB/RS-232/SNMP
11. Remote control function.
12. Protection against overload, over temperature, over charging, low battery.
Parameter
LED Model | LW500 | LW750 | LW1000 | LW1500 | LW2000 | LW2500 | LW3000 | LW4000 | LW5000 | LW6000 | LW7000 | |
LCD Model | / | / | LW1000-C | LW1500-C | LW2000-C | LW2500-C | LW3000-C | LW4000-C | LW5000-C | LW6000-C | LW7000-C | |
Nominal Power | 500W | 750W | 1000W | 1500W | 2000W | 2500W | 3000W | 4000W | 5000W | 6000W | 7000W | |
AC Input | Phase & waveform | Single Phase & Pure Sine Wave | ||||||||||
Norminal Voltage | 120VAC/230VAC OR 220/230/240VAC | |||||||||||
Acceptable Voltage | 95-126VAC OR 194-253VAC±4% | |||||||||||
Line Low Disconnect | 85V±4% OR 184±4% (154 wide mode±4%) | |||||||||||
Line Low Reconnect | 95V±4% OR 194 ±4%(164 wide mode±4%) | |||||||||||
Line High Disconnect | 136V±4%/274±4% | |||||||||||
Line High Reconnect | 126V±4%/264±4% | |||||||||||
Frequency | 50Hz(41-54) or 60Hz(51-64) (auto sensing) | |||||||||||
AC Output | Phase & Waveform | Single Phase & Pure Sine Wave (bypass mode sync to input) | ||||||||||
Voltage | 110/120/130VAC OR 220/230/240VAC±10%rms (bypass mode sync to input) | |||||||||||
Voltage Regulation | ±10%rms (bypass mode sync to input) | |||||||||||
Frequency | 50Hz±0.3Hz OR 60Hz±0.3Hz (bypass mode sync to input) | |||||||||||
Peak Power | 3 times of rating power | |||||||||||
Short Circuit Protection | Yes, shutdown after 10ms | |||||||||||
Power Factor | 0.9-1.0 | |||||||||||
DC Input | Battery Voltage | 12/24V dc | 12/24/48Vdc | 24/48Vdc | 48 | |||||||
Minimum Start Voltage | 10V for 12V, 20V for 24V, 40V for 48V | |||||||||||
Low Battery Alarm | 10.5±0.3Vdc for 12V, 21±0.6Vdc for 24V, 42V±1.2for 48V | |||||||||||
Low Battery Transfer | 10V±0.3Vdc for 12Vdc, 20V ±0.6Vdcfor 24V, 40V ±1.2Vdcfor 48V | |||||||||||
High Voltage Alarm | 16V±0.3 for 12V, 32V ±0.6for 24V, 64±1.2V for 48V | |||||||||||
High DC Input Recovery | 15.5±0.3Vdc or 31±0.6Vdc or 62V±1.2Vdc | |||||||||||
Max Charge Current | 15A20A/35A/50A/75A(According to the inverter model) | |||||||||||
Transfer Efficiency | Line Mode | >96% | ||||||||||
Battery Mode | >85% | |||||||||||
System Parameter | Power Saver | Load<=25W(Enabled on "P/S auto"setting of Remote Control | ||||||||||
Audible Alarm | Souding when the heat sink 's temperature is over 100ºCand shut down after 30 seconds | |||||||||||
Over Load Protection | 110%<Load<150%,beep 0.5s every 1s,and fault after 60s | |||||||||||
Load>150%,beeps 0.5s every 1s,and fault after 20s | ||||||||||||
Protections | low battery,over charging,over temp,over load | |||||||||||
Communications | RS-232/USB/SNMP(custom-made) | |||||||||||
Operating Environment | 0-40ºC,0-90%RH(non-condensing) | |||||||||||
Audible Noise | <60dB | |||||||||||
Net Weight(KG) | 8.5 | 8.5 | 14 | 18.5 | 18.5 | 23.6 | 23.6 | 34 | 37.5 | 46.5 | 46.5 | |
Dimension L X W X H(mm) | 380*182*160mm | 470×223×185mm | 650×223×185mm |
Trading terms for reference:
Delivery time: 7-15 work days
Payment terms: TT, LC, Western Union, Money gram.
Warranty: 2 years, 1%-2% spare parts.