Model NO.
SCB
Usage
Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Rockwell
Transport Package
Wooden
Specification
IEC/ANSI/IEEE. BS
Trademark
Rockwell
Origin
China
HS Code
8504220000
Production Capacity
10000

Product Description

6kV up to 35kV Dry Type Transformer with Cast Epoxy Resin 
Dry Type Transformer Technical Data: 


Dry Type Three Phase Distribution Transformer
Power-Cast transformers are available with specification as follows :

 
Rated Voltage HV coil : Up to 24kV  LVcoil : 0.48-4.16 KV
*Power-Cast transformers with multiple high voltage connections can also be supplied.
Tap Range Standard : ±2.5%, ±5%  Other ratings are available by arrangement.
Power Capacity Single phase : 20 - 2,000 KVA  Three phase : 50 - 10,000 KVA
Frequency : 50Hz, 60Hz   Typical % impedance voltage : 4-8%.
Connections HV coil : Delta  LVcoil : Wye with neutral point
* Other connections are available to meet requirements.
Temperature Ratings HV coil : Class F LVcoil : Class F
Max. ambient temperature : 450 C   Temperature rise limitation : 1800 C
 

1. Rated capacity : 30~16000kVA

2. Rated HV : 6kV to 35 kV

3. Frequency : 50Hz or 60Hz

4. Cooling methods : ONAN or ONAF

5. Tapping Range : ±5%   ±2x2.5%   ±4x2.5%

6. Regulator way : off-circuit-tap-changing or on-load-tap-changing

7. Phase : Single Phase or Three Phases

8. Connection Symbol : Yyn0 or Dyn11 or others

9. The altitude of installation could not be over 1000m;environment temperature should be less than 40

10. Coil temperature rise : 1000K

11. Cooling methods : AN or AF

12. Crust prevention class : IP00, IP20, IP23

13. Insulation class : F class

14. Insulation level:

     10KV,power frequency withstand voltage 35KV,thunder impact voltage 75KV

     20KV,power frequency withstand voltage 50KV,thunder impact voltage 125KV

     35KV,power frequency withstand voltage 70KV,thunder impact voltage 170KV

15. Product Standard : GB1094    GB6450     GB/T10228     DIN42523        IEC726

16. Can run in 100% relative humidity or other harsh environment.
 



Dry Type Three Phase Distribution Transformer
Dry Type Three Phase Distribution Transformer

Dry Type Three Phase Distribution Transformer
Dry Type Three Phase Distribution Transformer
Dry Type Three Phase Distribution Transformer Dry Type Three Phase Distribution Transformer

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours