Quality Isolation Transformer 25kVA (Three phase)

Looking for a top-notch 25kVA three-phase isolation transformer? Look no further! Our factory produces only high-quality transformers that are built to last. Contact us today!

Request a Quote
  • Quality Isolation Transformer 25kVA (Three phase)
  • Quality Isolation Transformer 25kVA (Three phase)
  • Quality Isolation Transformer 25kVA (Three phase)

PRODUCTS DETAILS

An Isolation transformer is the best way to establish a new neutral-ground bond, in order to correct common mode and other grounding problems.A transformer can provide conversion of a Delta system (3 wire) to a Wye connected (4 wire) system.The addition of an electrostatic shield adds further protection from some high frequency impulses and noise that might otherwise pass through the transformer via the inter-winding capacitance.A shielded isolation transformer provides excellent protection from all types of N-G disturbances (impulses, RMS voltage, and high frequency noise).It is critical that the transformer be grounded properly or common mode protection will be ineffective.MODERN designs and manufactures the highest quality isolation transformers.

Features and benefits:
1.High level of isolation
2.High quality neutral-ground bond
3.High level of common-mode noise rejection
4.Conversion from Delta to Wye or the other way around
5.Easy to change voltage taps
6.Custom design for specific system

Applications:
1.Integrated in power conditioner at input or output
2.Any system requires isolation and shielding

Typical application in power conditioner:

A.Isolation transformer(Delta/Wye) connected at input terminal:
1.If there is serious 3 rd harmonic and distortion in main supply, these disturbances can be reduced.
2.By Delta/Wye connection, producing new neutral line in output.Then prevent normal operation from poor condition of mains neutral.
3.The current wave distortion as 3 rd harmonic by non-linear load is isolated and without contaminating main supply.

B.Isolation transformer Wye/Delta connection at output terminal:
1.Current wave distortion by non-linear load is isolated and reduced.The contamination to main supply and stabilizer can be reduced and improved.
2.The current wave distortion effects the correction of output voltage sampling.But the signal at the primary of isolation transformer reflects the regular wave and the power conditioner may operate exactly.
3.If there is unbalance load, the power conditioner can run regularly.

Hot Products

Current Transformer Polarity Test Apparatus Automatic CT PT Tester Current Transformer CT Analyzer CT Tester Analysis

Current Transformer Polarity Test Apparatus Automatic CT PT Tester Current Transformer CT Analyzer CT Tester Analysis

Protection Current Transformer RS-40 Toroidal Current Transformer 40mm 100/5A-300/5A

Protection Current Transformer RS-40 Toroidal Current Transformer 40mm 100/5A-300/5A

Substation Current Transformer Jy-126 Busbar Current Transformer Ring Type Cts

Substation Current Transformer Jy-126 Busbar Current Transformer Ring Type Cts

Tp88 500/5A AC Current Transformer 1A Output Current Transformer Clamp CT

Tp88 500/5A AC Current Transformer 1A Output Current Transformer Clamp CT

Tp812 1200/5A 5va 0.5class Clip on Current Transformer Open Core Current Transformer

Tp812 1200/5A 5va 0.5class Clip on Current Transformer Open Core Current Transformer

High Voltage Low Current Transformer (MES-62/30) for Energy Meter Current Transformer

High Voltage Low Current Transformer (MES-62/30) for Energy Meter Current Transformer

Cp Series Current Transformer (MES-62/40) Current Transformer

Cp Series Current Transformer (MES-62/40) Current Transformer

AC Current Transformer for Energy Meter Measuring Current Transformer Cp80/40 Mes DIN Rail

AC Current Transformer for Energy Meter Measuring Current Transformer Cp80/40 Mes DIN Rail

Ict Cp-4 Series Encapsulated Interposing Current Transformer for Heyi Current Transformer Interposing CT

Ict Cp-4 Series Encapsulated Interposing Current Transformer for Heyi Current Transformer Interposing CT

Ict Cp-4 Series Encapsulated Interposing Current Transformer for Current Transformer Interposing CT

Ict Cp-4 Series Encapsulated Interposing Current Transformer for Current Transformer Interposing CT

Contact us

Ms. Cherry Lee: Please feel free to give your inquiry in the form below We will reply you in 24 hours