Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer

Discover the Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer for through-core protection. We are a factory specializing in high-quality transformers.
Request a Quote

PRODUCTS DETAILS

Basic Info.

Model NO.
LXK
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Transformation Ratio
60/1A-600/1A
Connection Type of Relay Coll
Series Connection/Parallel Connection
Relay Scale Value
15*1 30*1 15*2 30*2
Primary Residual Current of Relay Acting
2.4-4.5A 3-5A 3-6A
Weight
4.5kg
Rated Frequency
50/60Hz
Accuracy Class
5p10
Rated Output
1.0-15va
Inner Diameter
80,100,120,140,150,160,180,200,240,260,300mm
Transport Package
Carton
Specification
150*120*185mm
Trademark
CNKC
Origin
China
Production Capacity
5000PCS/Monthly

Product Description

Product Description
Zero sequence current transformer is suitable for use with DD-11/60 or DD-1/60 type relay and signal device in small grounding current system with rated frequency 50/60Hz and rated voltage 35kV and below, for residual (zero sequence) current detection and grounding protection, and at the same time make device components move, to achieve protection and monitoring.
LXK series residual (zero sequence) current transformers are cable type resin casting insulation indoor products, this series of zero sequence current transformers are open and close, epoxy resin casting structure, installation can be divided into two parts, and then merged into one, easy to install, Transformer inner diameter is φ 80, φ100, φ120, φ140, φ150, φ160, φ180, φ200, φ240, φ260, φ300 several specifications

Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer

Model Description
Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer
Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer

Product technical parameters and structure dimensions

Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer
Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer

Product features and scope of use 
1. The core of the current transformer has adoped amorphous alloy, it has high magnetic permeability, low saturation induction density and good stability.
2. High quality silicon steel sheet is taken to be the core of windings protection, which ensures the high accuracy limit factor.
3. The circular ring core and secondary windings are poured by high quality expoxies resin or polyurethane or silicon rubber in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance. the cable can cross the current transformer through its internal poles quickly and uniformly.
Ambient temperature:-10ºC-+40ºC
Relative humidity:The average humidity of a day should be no more than 95%. The average humidity of a month should be no more than 90%.
Earthquake intensity: not exceed 8 degrees.
Saturated vapor pressure the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more
Than1.8Kpa;
The height above sea level:≤1000 m (Except special requirements)
It should be installed in the places without fire, explosion, serious filth, and chemical erosion and violent vibration.


Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer

Product details
Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer

Products real shot

Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer

A corner of the production workshop
Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer

Product packaging

Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer

Product application case
Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer
Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer Lxk-80/100/120mm 10/35kv Indoor Hv Zero-Sequence Current Transformer Opening and Closing Type Through-Core Protection Transformer
 
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours