Basic Info.
Model NO.
MS-150-27
Voltage Regulating Mode
Frequency Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
Two-way Transmission
Modulation System
PFAW
Certification
CE, RoHS
Brand
Weho
Hold up Time
30ms/230VAC 12ms/115VAC at Full Load
Voltage Range
85 ~ 264VAC 120 ~ 373VDC
Frequency Range
47~63Hz
Efficiency
89%
Leakage Current
<0.75mA / 240VAC
Transport Package
Carton or Plywood Case
Specification
99mm*82mm*30mm
Trademark
Weho
Origin
Zhejiang
Production Capacity
50000/Year
Product Description
Constant Voltage Mini size MS-150-27 150Watt 27V Ac to Dc Single Output Transformer
Features:
1.Full range AC 85-264V Input
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty
Model | MS-150-12 | MS-150-15 | MS-150-24 | MS-150-27 | MS-150-36 | MS-150-48 |
DC output voltage | 12V 0~12.5A | 15V 0~10A | 24V 0~6.5A | 27V 0~5.5A | 36V 0~4.17A | 48V 0~3.13A |
Wave and noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet wire stabilily | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 83% | 84% | 86% | 86% | 86% | 86% |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
Input voltage range | 90~132VAC/180~264VAC by switch 254~370VDC 47~63Hz | |||||
Impact current | Cold start current 15A/115VAC 30A/230VAC | |||||
Overload protection | 105% -150% cut off the output, automatic recovery | |||||
Over voltage protection | ||||||
Setup, rise, hold up time | 200ms, 50ms, 20ms/230VAC at full load | |||||
Withstand voltage | I/P-O/P: 1.5kV I/P-FG: 1.5kV OP-FG: 0.5kV 1 minute | |||||
Isolation resistance | I/P-O/P I/P-FG O/P-FG: 500VDC/100MΩ | |||||
Working temperature | -10ºC~+50ºC | |||||
Dimension | 159 x 98 x 38mm | |||||
Weight | 0.55kg | |||||
Packing | 34 x 32 x 24CM/30PCS/16.5kg |